Measurement of oxygen transfer in clean water

ASCE standard, ASCE/SEI 2-06
  • 3.80 MB
  • 1786 Downloads
  • English

American Society of Civil Engineers , Reston
Water -- Aeration -- Measurement -- Standards., Water -- Dissolved oxygen -- Measurement -- Stand
StatementAmerican Society of Civil Engineers.
ContributionsAmerican Society of Civil Engineers.
Classifications
LC ClassificationsTD458 .M42 2007
The Physical Object
Paginationp. cm.
ID Numbers
Open LibraryOL17557015M
ISBN 100784408483
ISBN 139780784408483
LC Control Number2006102612

Abstract. Measurement of Oxygen Transfer in Clean Water was developed to calculate the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water. The Standard is applicable to laboratory-scale oxygenation devices with small volumes of water as well as to full-scale systems with water volumes typical of those found in the activated sludge wastewater treatment process.

Abstract. Measurement of Oxygen Transfer in Clean Water provides the latest methods for measuring the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water.

This Standard (a revision of ASCE ) is applicable to laboratory scale oxygenation devices with water volumes of a few gallons as well as to full-scale systems with water volumes typical of those found in. Measurement of Oxygen in Clean Water, ASCE/SEIprovides the latest methods for measuring the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water.

A complete revision of ANSI/ASCEthis Standard represents the current consensus of the ASCE Committee on Oxygen Transfer Standards. : Measurement of Oxygen Transfer in Clean Water/Book and Disk (Asce Standard) (): Not Available: BooksFormat: Paperback.

Measurement of Oxygen Transfer in Clean Water provides the latest methods for measuring the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water. This Standard (a revision of ASCE ) is applicable to laboratory scale oxygenation devices with water volumes of a few gallons as well as to full-scale systems with water volumes typical of those found in the.

Download Measurement of oxygen transfer in clean water FB2

This paper presents the experiments on measurement of oxygen transfer capacity in clean water by using desorption and absorption techniques. Experiments were set up in a small-scale tank with a. Measurement of Oxygen Transfer in Clean Water, ASCE/EWRI (Asce/Ewri Standard) by Michael K. Stenstrom; 2 editions; First published in ; Subjects: Water, Dissolved oxygen, Measurement, Aeration, Standards.

oxygen concentration in clean water (desorption measurement). While sodium sulfite was added to decrease the dissolved oxygen concentration in absorption measurement.

Standard oxygen transfer coefficient (K L a 20) was calculated based on the variation of dissolved oxygen concentration with time. For the absorption method, a mean value of K L File Size: 98KB. Measurement of Oxygen Transfer in Clean Water was developed to calculate the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water.

The Standard is applicable to laboratory-scale oxygenation devices with small volumes of water as well as to full-scale systems with water volumes typical of those found in the activated sludge wastewater treatment process.

Content Description. Measurement of Oxygen in Clean Water, ASCE/EWRIprovides the latest methods for measuring the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water.A complete revision of ANSI/ASCEthis Standard represents the current consensus of the ASCE Committee on Oxygen Transfer Standards.

* Consult the ASCE, Measurement of Oxygen Transfer in Clean Water, for more information on oxygen transfer protocols. 4 INTRODUCTION The Air Diffusion Systems (ADS) fine bubble aeration system (originally created by J.

Nelson Hinde inand now owned. Measurement of Oxygen in Clean Water, ASCE/SEIprovides the latest methods for measuring the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water.

A complete revision of ANSI/ASCEthis Standard represents the current consensus of the ASCE Committee on Oxygen Transfer Range: $ - $ Get this from a library. Measurement of oxygen transfer in clean water: ASCE standard, ASCE/EWRI [American Society of Civil Engineers.;].

Get this from a library. A standard for the measurement of oxygen transfer in clean water. [American Society of Civil Engineers.]. Alternative Methods for Evaluation of Oxygen Transfer Performance in Clean Water Ingrid Fändriks Aeration of wastewater is performed in many wastewater treatment plants to supply oxygen to microorganisms.

To evaluate the performance of a single aerator or an aeration system, there is a standard method for oxygen transfer measurements in clean.

Details Measurement of oxygen transfer in clean water PDF

"Measurement of Oxygen in Clean Water, ASCE/SEI " provides the latest methods for measuring the rate of oxygen transfer from diffused gas and mechanical oxygenation devices to water.

A complete revision of ANSI/ASCEthis Standard represents the current consensus of the ASCE Committee on Oxygen Transfer Standards. the Measurement of Oxygen Transfer in Clean Water. The Standard was subsequently improved, updated and republished in and will be published again in Following the development of the Clean Water Standard, it was realized that the next most important gap in knowledge was the characterization of process water transfer Size: KB.

oxygen transfer in clean water aeration systems may have a clean water efficiency of 6 to % SOTE/m and 3 to 4% Power Measurement • Since aeration systems are competitively bid on the basis of oxygen transfer per unit of power consumed, power measurement becomes very importantFile Size: 2MB. Process water conditions for oxygen transfer are best described by mass transfer parameters.

This dissertation focuses on quantifying the volumetric mass transfer coefficient, KLa, and the liquid film coefficient, KL, using dynamic surface tension (DST) measurements. The maximum bubble pressure method was selected to measure DST because. Table of Contents for Measurement of oxygen in clean water: ASCE standard, ASCE/SEI / American Society of Civil Engineers, available from the Library of Congress.

In order to evaluate the performance of different types of aeration systems, the American Society of Civil Engineers (ASCE) and US EPA jointly developed a standard for the measurement of oxygen transfer in Clean Water in The Standard was subsequently improved, updated, and.

DIN EN Wastewater treatment plants - Part Measurement of the oxygen transfer in clean water in aeration tanks of activated sludge plants Kläranlagen - Teil Messung der Sauerstoffzufuhr in Reinwasser in Belüftungsbecken von Belebungsanlagen/5(5). In order to determine the standard oxygen transfer rate (SOTR) of the aerators in the carrousel, six experiments, according to the Dutch standard method (STORA, ), were carried out by previous investigators, in Augustas carrousel was first closed, and then it was filled with suitable clean water (16 mg COD/l).Cited by: Aeration testing is conducted to the ASCE (American Society of Civil Engineers) standard "Measurement of Oxygen Transfer in Clean Water" (ASCE/EWRI ).

Tests can be conducted on a wide range of aeration devices including fine bubble diffused aeration systems, coarse bubble aeration systems, surface aerators, jet aeration systems and venturi. SOTR is the Standard Oxygen Transfer Rate of an aeration system determined by measurement of non-steady state oxygen uptake in clean water, which is measured following the test protocol detailed in the American Society of Civil Engineers, ASCE, Measurement of Oxygen Transfer in Clean Water, ANSI/ASCE Second Size: KB.

Measurement of oxygen transfer from air into organic solvents Article (PDF Available) in Journal of Chemical Technology & Biotechnology 91(3):n/a-n/a November with Reads. dissolved oxygen content in water quality monitoring is an important indicator.

Dissolved Oxygen (DO) refers to oxygen dissolve in water molecules state, DO is vital for all higher aquatic life (B.A. Cox,;M.A. Best, ). A source of DO is atmospheric oxygen infiltrate water body when dissolved oxygen in water is not. Gas mass transfer through the liquid-gas interface has enormous importance in various natural and industrial processes.

Surfactants or insoluble compounds adsorbed onto an interface will inhibit the gas mass transfer through the liquid-gas surface. This study presents a technique for measuring the oxygen mass transfer through the air-water by: Measurement procedures for determination of α have been debated at length.

Description Measurement of oxygen transfer in clean water FB2

Unlike clean water oxygen transfer measurement, no standard has been developed for process water oxygen transfer, however a standard guideline has been published by a joint committee of WEF and ASCE6. The clean water oxygen transfer capabilities of the Mazzei AirJectionFile Size: 1MB. Field Measurement of Dissolved Oxygen Field DO Measurement()_AF.R4 Effective Date: Ap 1 General Information.

Purpose. This document describes methods and considerations to be used and observed when conducting field measurements of dissolved oxygen. Oxygen mass transfer experiments were performed using a dynamic method based on the measurement of the concentration of dissolved oxygen in water.

A step change in the concentration of inlet gas results in a dynamic response in the concentration of oxygen dissolved in the liquid phase, and these temporal concentration data are used to Cited by: Instrumentation for water industry applications Micro Motion ELITE CMFS Meter Reliable two-phase mass flow measurement for ultimate performance in even the most demanding field and plant applications.

± g/cm³ liquid density accuracy Best-in-class gas mass flow accuracy of ±% Entrained gas diagnostic.It is a more modern method of dissolved oxygen measurement. Be sure to note down the value in the probe’s calibration record book.

Find out more about how to measure Dissolved Oxygen in water or get further support by getting in touch with us via our contact form on this page or Accuracy: 0 – %: ± 1% of reading. % – %: ± 10%.